رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.500 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.875 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, single throw, normally open
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 plug-in
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
220.0 ac
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
1.0 ac
MRC:
The amount of voltage for which the heater is designed,expressed in volts.CYCU
Heater Voltage Rating In Volts:
6.3
MRC:
The rated power that the heater can safely consume,measured in watts.CYCV
Heater Power Rating In Watts:
2.5
MRC:
A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
Delay Time In Seconds:
30.0 fixed operate
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 pin