رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Capacitor Assembly
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.414 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Terminal
MRC:
The relative level of the number of electric charge at a given potential which the capacitor is capable of receiving and storing.AEAU
Capacitance Value:
22.0 microfarads
MRC:
The limits of permissible percent deviation of capacitance value of an item from its rated value.AEAW
Capacitance Tolerance In Percent:
-10.0 to 10.0
MRC:
The number of components included in the item.AJJW
Component Quantity:
4 and 1
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
4 holes 0.120 diameter 2.250 c-to-c along length x 1.500 c-to-c along width
MRC:
The name of the government agency or commercial organization that controls the component.AQHK
Component Controlling Agency:
Department of defense, departmentof defense
MRC:
The name of the component assigned by the controlling agency.AQHL
Component Name:
Electrolytic fixed capacitors, terminal board
MRC:
The specific number used to identify the component.AQHM
Component Identifying Number:
-39003/01-2380 type no. And ms27249-3b1 part no.
MRC:
The means used for electrical connection.ATYJ
Electrical Connection Method:
Parallel
MRC:
The criteria determining the functional relationship of the components.ATYM
Component Relationship:
Connected matched pair
MRC:
The maximum sustained voltage that can safely be applied to an electric device without risking the possibility of a breakdown.ATYY
Working Voltage Rating:
50.0 volts