رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Direct operated pressure reducing valve, of sandwich plate design, for use in vertical stacking assemblies
TXT
وصف:
Fluid Pressure Regulating Valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Petroleum base fluid
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
4600.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
3050.0 pounds per square inch
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Alofts sonar system model 980 (v1)
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Screw adjustment with locknut and protective cap; internally piloted, externally drained; without reverse free-flow check valve; sae threads; operating pressure, inlet, 4600 psi; back pressure port t, y 2320 psi; maximum permissible flow 13.2 gpm; approx weight 2.6 lb