رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Thermostatic Switch
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b all threaded hole
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.470 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.740 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.700 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
96.0 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
6.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.375 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Base and unthreaded hole and threaded hole
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.190 inches all threaded hole
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
24.0 amperes resistive load first voltage and 17.0 amperes motor load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
24.0 amperes resistive load second voltage and 17.0 amperes motor load second voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
-35.00/+95.00 actuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External actuation point screw with scale
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level second voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf all threaded hole