رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Parts kit gas anesthesia apparatus
TXT
وصف:
Gas Anesthesia Apparat Parts Kit
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Abrasion resistant
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
112.000 cubic inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately delicate
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Gas anesthesia apparatus mdl 2, 3, 4000
MRC:
The unusual or unique characteristic/s/ or quality/ies/ of an item which necessitates the establishment of a requirement for special handling.BBRJ
Special Handling Feature:
Fragile
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to measure oxygen flow in series 2, 3, 4000 unitrol and wall arm anesthesia gas machine
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
0.080 cubic feet
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Replacement low oxygen flow kit; c/o screw 2-56 x 0.187 in. Lg 3; gasket 0.250 in. Id x 0.500 in. Od x 0.062 in. Thk polyethylene 1; gasket 0.250 in. Id x 0.531 in. Od x 0.030 in. Thk polyethylene 1; gasket beveled 0.687 in. Od x 0.562 in. Id x 0.093 in. Thk polyethylene 1; flow tube glass 11.250 in. Lg x 0.468 in. Od x 0.250 in. Id w/black line 0.250 in. Lg 0.875 in. From base of tube 1; gasket 0.250 in. Id x 0.125 in. Thk, ethylpropylene rubber 70 durometer 1; stop float, upper polyethylene moulded nylon 1; scale flowmeter o2 green 10.875 in. Lg x 0.625 in. W x 0.250 in. Thk, 20 to 700 ml per min 1; package, tube polyethylene 1; shipping container 1; gasket fiber 0.812 in. Id x 0.562 in. Od x 0.031 in. Thk 1; 176-1296-000 installation instructions 3 pages; plate inst warning 2; stop float lower 1; container gasket 1; tube package 1
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Anesthesia apparatus