رقم الجزء 0287003.L

Inclosed Link Fuse

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
0287003.l
تجريد:
صلاحيه:
وحدة القياس:
NIIN:
016487653
NSN
رقم المخزون الوطني:
5920-01-648-7653 5920016487653
TXT
وصف:
Inclosed Link Fuse
INC
INC
رمز اسم العنصر:
00249
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Plug-in autofuse
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.1 millimeters
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
6.5 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
18.8 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.1 millimeters
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
3.0
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Unable To Decode:
4.1 millimeters
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
32.00 dc
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Time delay
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Visible element
MRC:
The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
Circuit Over-current Interruption Delay Time In Seconds:
600.0 135 pct of current rating
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
1000.0

{lang[cimilar]} Inclosed Link Fuses

« Fuses, Arrestors, Absorbers and Protectors {lang[catalog]}
قارن الآن»
واضح | أخفى