رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
03-330-133mk001
TXT
وصف:
Immersion Thermocouple
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABXG
Overall Length:
7.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+75.0/+200.0 degrees fahrenheit
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Npt
MRC:
Indicates the type of unit.APQB
Unit Type:
Protective tube
MRC:
The american wire gage size of the accommodated wire.AXNX
Accommodated Wire Awg Size:
20
MRC:
A measurement of the longest dimension of the immersed portion of the item,in distinction from width.BKBW
Immersion Length:
2.500 inches
MRC:
The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
Mounting Thread Quantity:
27 per inch
MRC:
The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
Mounting Facility Screw Thread Diameter:
0.125 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Ceramic individual wire insulation
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel protective tube
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw