رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Directional Control Linear Valve
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
26.0 gallons per minute
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ballast sys
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
4600.0 pounds per square inch hydraulic fluid, mineral base
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
176.0 degrees fahrenheit hydraulic fluid, mineral base
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The number of spools provided.CYHB
Spool Quantity:
1
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0