رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
088-01841wobrakeassy
معلومات الجزء
length includes brake housing; motor length without brake housing 45.000 inches
TXT
وصف:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
22.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
54.188 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
29.438 inches
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.625 inches first end
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.750 inches second end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.313 inches first end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.375 inches second end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
2.875 inches second end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
2.750 inches first end
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
3.000 inches second end
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
5.625 inches first end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise second end or counterclockwise second end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise first end or counterclockwise first end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open protected
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The acceptable time limits for the item.BFLT
Time Interval:
30.0 minutes on
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Fan cooled
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
8.000 cubic feet
MRC:
A designation indicating the frame size by which the item is identified.CNMM
Frame Size Designation:
445tz
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
50.000 horsepower input
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
3.625 inches second end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
8.500 inches first end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
16.500 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
50.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
820.0 low full load and 1695.0 high full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
18.000 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
62.000 low input or 80.000 high input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
450.0 line to line single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 single style first end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 single style second end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 wire lead