رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The length of a straight line which passes through the center of an aperture,and terminates at the circumference.ABVL
Aperture Diameter:
0.250 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Open
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Socket (tube) all ends
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube all ends
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal or vertical
MRC:
The difference,at the rated temperature,between the inlet and outlet pressure for positive operation.CQCP
Inlet/outlet Operating Pressure Differential:
300.0 pounds per square inch
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
187.0 dc
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.500 inches all ends
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy seat
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090