رقم الجزء 10-30653-1

Primary Expulsion Fuse Cutout

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
10-30653-1
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
010097719
NSN
رقم المخزون الوطني:
5920-01-009-7719 5920010097719
TXT
وصف:
Primary Expulsion Fuse Cutout
INC
INC
رمز اسم العنصر:
05385
MRC:
The formation identifying the structural characteristic of the item.AAJG
Construction:
Inclosed
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Any acceptable
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.980 inches and 2.020 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 0.969 inches and 1.031 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.760 inches and 1.800 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The means of attaching the item.ADJH
Mounting Method:
Holes
MRC:
Indicates the type of fuse the item is designed to accommodate.AFWL
Fuse Type Accommodated:
Cartridge
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
External fuel tank release
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Two 0.203 in. Maximum diameter unthreaded holes spaced 1.520 in. Maximum c to c along the length
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.0
MRC:
Indicates the design type of the item.APGF
Design Type:
Nondropout
MRC:
The number of fuses provided.AQAT
Fuse Quantity:
2
MRC:
An indication of whether or not an indicating feature is included.AQDQ
Indicating Feature:
Not included
MRC:
The means by which reclosure is effected.AQDR
Reclosing Method:
Manual
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0