رقم الجزء 10049528-2

Power Transformer

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
10049528-2
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
004269602
NSN
رقم المخزون الوطني:
5950-00-426-9602 5950004269602
TXT
وصف:
Power Transformer
INC
INC
رمز اسم العنصر:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not establishednot established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.406 inches 1.406 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.406 inches 1.406 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches 1.000 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.125 inches single group0.125 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2.0 kilohertz single component and 2.0 kilohertz single component and 150.0 kilohertz single component150.0 kilohertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single componentsingle phase to single phase single component
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
145.0 degrees celsius145.0 degrees celsius
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.094 inches single mounting facility single center group and 1.094 inches single mounting facility single center group and 1.219 inches single mounting facility single center group1.219 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealedhermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and flange single group and slot single groupslot single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 primary single component and 1 secondary single component1 secondary single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tinned wire leads
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
19.0 microamperes ac single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
8.00 ac volts single component single primary8.00 ac volts single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
8.00 ac volts single component single secondary8.00 ac volts single component single secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 tab, solder lug

{lang[cimilar]} Power Transformers

« Coils and Transformers {lang[catalog]}
قارن الآن»
واضح | أخفى