رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Radio Frequency Transmissio Line
MRC:
The length of a straight line which passes through the center of an item,and terminates at the outside circumference.ABHE
Outside Diameter:
Between 0.1404 inches and 0.1430 inches
MRC:
The wire gage designation and the gage number used to describe the conductor size.ACVL
Conductor Size:
19 awg
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
500.0 watts average
MRC:
The reactance-resistance complex value which must be matched by the transmission line and termination to achieve lowest standing wave ratio,expressed in ohms.AJDD
Characteristic Impedance In Ohms:
50.0
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
1
MRC:
The element,compound,or mixture of which the conductor is fabricated,excluding any surface treatment.APYQ
Conductor Material:
Steel
MRC:
The electrical capacitance measured between two specified points on the item,expressed in picofarads per unit length.APZA
Capacitance In Picofarads Per Unit Length:
29.1 per foot
MRC:
The voltage rating at which the item is designed to operate.APZB
Operating Voltage Rating:
5.0 kilovolts
MRC:
An indication of whether or not the item includes an outer conductor.APZC
Outer Conductor:
Included
MRC:
The physical configuration of the insulation spacer.APZD
Insulation Spacer Shape:
Tubular
MRC:
The element,compound,or mixture from which the insulation spacer is fabricated,excluding any surface treatment.AQAZ
Insulation Spacer Material:
Plastic, polytetrafluoroethylene
MRC:
The length of a straight line which passes through the center of the insulation spacer,and terminates at the outside circumference.AQBA
Insulation Spacer Outside Diameter:
0.118 inches
MRC:
An indication of whether or not a terminal fitting/s/ is included.AQBD
Terminal Fitting:
Included
MRC:
Indicates the type of conductor the item is designed to accommodate.AQCE
Accommodated Conductor Type:
Coaxial
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the conductor.AQRW
Conductor Surface Treatment:
Copper clad and silver plated
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the outside circumference.AQRX
Tubing Outside Diameter:
Between 0.1404 inches and 0.1430 inches
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the inside circumference.AQRY
Tubing Inside Diameter:
Between 0.116 inches and 0.120 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Copper
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Tin plated
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment