رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Fungus proof per mil-t-152
TXT
وصف:
Radio Frequency Transmissio Line
MRC:
The length of a straight line which passes through the center of an item,and terminates at the outside circumference.ABHE
Outside Diameter:
0.141 inches
MRC:
The wire gage designation and the gage number used to describe the conductor size.ACVL
Conductor Size:
19 awg
MRC:
The reactance-resistance complex value which must be matched by the transmission line and termination to achieve lowest standing wave ratio,expressed in ohms.AJDD
Characteristic Impedance In Ohms:
50.0
MRC:
The specification,standard,or the number or symbol of the manufacturer used to identify the termination.AJDF
Termination Identification:
10279283 and 10279284
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
2
MRC:
The element,compound,or mixture of which the conductor is fabricated,excluding any surface treatment.APYQ
Conductor Material:
Copper, qq-w-343, soft
MRC:
The electrical capacitance measured between two specified points on the item,expressed in picofarads per unit length.APZA
Capacitance In Picofarads Per Unit Length:
29.3 per foot
MRC:
An indication of whether or not the item includes an outer conductor.APZC
Outer Conductor:
Included
MRC:
The physical configuration of the insulation spacer.APZD
Insulation Spacer Shape:
Tubular
MRC:
The element,compound,or mixture from which the insulation spacer is fabricated,excluding any surface treatment.AQAZ
Insulation Spacer Material:
Plastic, mil-p-19468
MRC:
The length of a straight line which passes through the center of the insulation spacer,and terminates at the outside circumference.AQBA
Insulation Spacer Outside Diameter:
0.101 inches
MRC:
The name of the government agency or commercial organization controlling the termination.AQBB
Termination Controlling Agency:
U. S. Army missile command
MRC:
An indication of whether or not a terminal fitting/s/ is included.AQBD
Terminal Fitting:
Included
MRC:
Indicates the type of conductor the item is designed to accommodate.AQCE
Accommodated Conductor Type:
Coaxial
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the outside circumference.AQRX
Tubing Outside Diameter:
0.141 inches
MRC:
The length of a straight line which passes through the center of the tubing,and terminates at the inside circumference.AQRY
Tubing Inside Diameter:
9.101 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Copper, ww-t-799
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy 102 or copper alloy 120 or copper alloy 122
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Conductor external surface silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Tin plated, mil-t-10727
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment