رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-16 lru blower; nha 1041-1
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
6000.0 feet
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
182.0 ac pounds per hour dry 1st alternate operating power rqmt and 222.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
106.0 ac pounds per hour dry 2nd alternate operating power rqmt and 128.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+10.0/+36.0 degrees celsius
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection