رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Metallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
1.438 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.072 inches 1st end
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
1.772 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the inner conveying tube.ADJL
Inner Conveying Tube Style:
Overlapped square locked unpacked
MRC:
The hue or tint of the exterior of the item.ADJS
Exterior Color:
Natural
MRC:
The length of a straight line which passes through the center of the flange,and terminates at the outside circumference.AEPR
Flange Outside Diameter:
1.772 inches 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain 1st end
MRC:
The design used in constructing the end portion of the flange.AKUT
End Flange Construction:
Solid 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Plain face flange 1st end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Identical ends
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
600.0 pounds per square inch
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer braided corrosion resistant steel wire
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
150.0 pounds per square inch
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
300.0 pounds per square inch
MRC:
The type of protection provided by the outer covering.CRJM
Outer Covering Environmental Protection:
Corrosion resistant
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
22.500 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Round w/ out bolt holes 1st end