Protective shield
TXT
وصف:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
26.000 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.625 inches
MRC:
The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
Inlet Bolt Circle Diameter:
3.875 inches
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
10, 20, 30, 40, 50, 60, 70, 80, 90, 100
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.0/+86.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
1.500 in. Ips
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
3.875 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.625 inches
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Not included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Guided
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, stainless
MRC:
Indicates the type of guide provided.BMHW
Guide Type:
Solid rod
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
150.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
1.500 in. Ips
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Vertical
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included