رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
El Engine Starter Relay-solenoid
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.280 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.380 inches
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
1.750 in. C to c
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
12.0 volts
MRC:
The voltage rating at which the item will close.AWZB
Closing Voltage Rating:
Between 2.6 volts and 6.6 volts
MRC:
The voltage rating at which the item will open.AXAY
Opening Voltage Rating:
Between 0.6 volts and 2.1 volts
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
Between 52.6 amperes and 59.0 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
Between 12.7 amperes and 14.3 amperes
MRC:
The measured distance of the plunger stroke.AXBD
Plunger Stroke Length:
0.812 inches
MRC:
An indication of whether or not engaging linkage is included.AXBE
Engaging Linkage:
Not included
MRC:
Designates the thread diameter and number of threads per measurement scale of the accommodated linkage threaded hole.AXBY
Accommodated Linkage Threaded Hole Thread Size:
1/2-13
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Not included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
2
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Screw
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Included
MRC:
The number of main terminals provided.AXHJ
Main Terminal Quantity:
2
MRC:
Indicates the type of main terminal/s/ provided.AXHK
Main Terminal Type:
Stud
MRC:
The number of control terminals that are internally connected to the main terminals.AXHM
Control Terminal Quantity Internally Connected To Main Terminal:
1
MRC:
The diameter of the motor for which the rigid mount is designed.AXHN
Motor Diameter For Which Rigid Mount Is Designed:
5.560 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slot
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Cadmium
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Cadmium plated