رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Headless Straight Pin
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the first end.AAGZ
First End Style:
Chamfered
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the holes.ABRB
Hole Arrangement Style:
One end drilled
First Hole Diameter:
Between 0.140 inches and 0.155 inches
Distance From Centerline Of Hole To End Of Pin:
0.310 inches
MRC:
The overall dimension measured along the longitudinal axis,with terminated points at the extreme ends of the pin.ACHT
Pinlength:
2.000 inches
MRC:
The overall length of a straight line which passes through the center of the pin,and terminates at the outside circumference.ACHU
Pindiameter:
Between 0.6240 inches and 0.6250 inches
First End Taper Length:
Between 0.030 inches and 0.060 inches
MRC:
Indicates whether or not the second end is identical to the first end.CQBB
Second End Relationship With First End:
Identical
First End Taper Angle:
45.0 degrees
MRC:
Designates the specific surface roughness rating,representing the arithmetic average deviation of the surface from the meanline in profile.CSYM
Surface Finish:
63.0 microinches outside diameter
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 1008 or steel comp 1010 or steel comp 1012 or steel comp 1015 or steel comp 1016 or steel comp 1017 or steel comp 1018 or steel comp 1020 or steel comp 1023 or steel comp 1025
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Cadmium and chromate
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Qq-p-416, type 2, cl 2 federal specification single treatment response