رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Engine Generator Regulator
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector, receptacle w/external contacts err-100 err-100
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector, receptacle w/internal contacts err-100 err-100
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant err-100 err-100
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus resistant err-100 err-100
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Watertight err-100 err-100
MRC:
An indication of whether or not the item is provided with a self-contained shock mount.AGBC
Shock Mount:
Not provided
MRC:
An indication of whether or not shielding against radio interference is provided.ALBH
Radio Interference Shielding:
Provided
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
28.0
MRC:
The electrical voltage of the system for which the item is designed.ANYC
System Voltage Rating:
28.0
MRC:
Indicates the type of ground the electrical system utilizes.ANYD
System Ground Polarity:
Negative
MRC:
Indicates the type of device used to maintain a constant voltage.ANYE
Voltage Regulator Unit Type:
Transistor
MRC:
The number of individual voltage regulator units contained in the item.ANYH
Voltage Regulator Unit Quantity:
1
MRC:
Indicates the type of device used to close and open (break) the circuit.ANYR
Circuit Control Device Type:
Circuit breaker
MRC:
The cut-in voltage/s/ required to close the circuit.ANYS
Cut-in Voltage Rating:
27.2
MRC:
The cutout voltage/s/ required to open /break/ the circuit.ANYX
Cutout Voltage Rating:
28.8
MRC:
The discharge /cutout/ current/s/ required to open /break/ the circuit,expressed in amperes.ANYZ
Cutout Current Rating In Amps:
23.0 err-100 err-100
MRC:
The discharge /cutout/ current/s/ required to open /break/ the circuit,expressed in amperes.ANYZ
Cutout Current Rating In Amps:
27.0 err-100 err-100
MRC:
An indication of whether or not a reverse current overload circuit breaker is included.ANZB
Reverse Current Overload Circuit Breaker:
Included
MRC:
An indication of whether or not a field relay unit is included.ANZC
Field Relay Unit:
Included
MRC:
An indication of whether or not the terminal(s) is encased.ANZE
Terminal Encasement:
Encased