رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Anodized
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external tube
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.380 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the packing is fabricated.ADQT
Packing Material:
Rubber
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Needle
MRC:
Indicates the type of renewable seating ring in the item.ADZH
Renewable Seat Ring Type:
Threaded
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Flange
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+20.0/+21.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
1st stage automatic, 2nd stage manual
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Screw
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The means whereby a valve is actuated other than by the media passing through it.AEVS
Remote Actuation Method:
Piston
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
65.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
20.0 pounds per square inch