رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Actuation point-increasing temp 375 degrees plus or minus 10 degrees f; ambient temp rating minus 65 degrees to plus 275 degrees f; media temp rating minus 65 degrees to plus 300 degrees f; proof temp 435 degrees f; proof pressure 75 psig; burst pressure 150 psig; switch in hermetically sealed chamber
TXT
وصف:
Thermostatic Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 4.160 inches and 4.450 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 0.120 inches and 0.180 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 1.970 inches and 2.230 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
Between 1.350 inches and 1.510 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
Between 0.320 inches and 0.380 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
Between 0.120 inches and 0.180 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
The shortest straight line between flats,perpendicular to the height.ASDB
Width Across Flats:
0.680 inches
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
300.0 milliamperes resistive load single voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level single voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas