رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
O/a jacket thermoplastic elastomer; dwg title harness assembly, dc receiver cabinet
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-60.0 degrees celsius and 125.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Next generation radar (nexrad)
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Terminal lug 2nd end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Terminal lug 1st end all conductors
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Power
MRC:
The means by which the item is bound.AMEM
Binding Method:
Sleeve and tape laced and wire bound
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
7
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
43.500 inches 1st conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
44.500 inches 2nd conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
49.000 inches 5th conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
45.500 inches 3rd conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
47.750 inches 4th conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
52.000 inches 7th conductor
MRC:
A measurement of the longest dimension of a conductor,in distinction from width.APYS
Conductor Length:
50.750 inches 6th conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
14 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
27 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
7 singles
MRC:
The number of groups into which two or more conductors are arranged.CXDT
Group Quantity:
1
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
5 term lug ms25036-106; 1 term lug ms25036-153; 1 term lug ms25036-156 1st end all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
5 term lug ms25036-106; 3 term lug ms25036-153 2nd end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
96906 both ends all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum 2nd position shield foil cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 3rd position shield braid, metallic cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic fluorinated ethylene propylene 1st position primary insulation all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin 3rd position shield braid, metallic cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors