رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Material is insulation sleeving, class 3, spec mil-i-23053/5
TXT
وصف:
Electrical Insulation Sleeving
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Any acceptable
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 135.0 degrees celsius
Expanded Inside Diameter:
1.250 inches
Recovered Inside Diameter:
0.625 inches
Recovered Wall Thickness:
0.040 inches
MRC:
The percentage an item is rated to reduce in size upon the application of heat.AGAU
Heat Shrinkage Rating In Percent:
50.0
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1800 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyolefin
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Shrinkable
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
19207-12295791-11 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
1000.0 volts per military /0.001 inch/