رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Used w/high pressure sodium lamps and p/n 14320-14 stepdown transformer
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
3
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.188 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.203 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
4
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the center to center distance between the mounting holes along the length.ADHV
Center To Center Distance Between Mounting Holes Along Length:
2.188 inches
MRC:
A measurement of the center to center distance between the mounting holes along the width.ADHW
Center To Center Distance Between Mounting Holes Along Width:
1.750 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Holes
MRC:
The number of lamps that can be accommodated by the item.AEUH
Lamp Accommodation Quantity:
1
MRC:
The rated power that a lamp can safely consume or provide,measured in watts.AEWS
Lamp Wattage Rating In Watts:
35.0
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.680
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 120.0 volts and 277.0 volts
MRC:
The characteristic of the power factor.ARGL
Power Factor Characteristic:
High
MRC:
The starting characteristic of the item.ARQF
Starting Characteristic:
Preheat
MRC:
An indication of whether or not a starter is required.ARQG
Starter:
Required
MRC:
The position and quantity of terminals for making connection to the item.ARQH
Terminal Location And Quantity:
2 one end and 1 other end