رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.450 inches
MRC:
The length measured from the element to the extreme end of the power cable.ABJP
Power Cable Length:
120.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
120.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.500 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Cable
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 0.0 degrees fahrenheit and 140.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Thread
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Single pole, double throw, momentary
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Sea water
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
0.905 inches
MRC:
The relationship between the position of the float and the position of the contacts.CWTL
Float And Contact Positions:
Float up, contacts open and float down, contacts closed
MRC:
The number of alternating current phases.FAAZ
Phase:
Single