Inlet and outlet fittings to retain 0.250 in. Id by 0.500 in. Od hose
TXT
وصف:
Reciprocating Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
4
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded external
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
4
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded external
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
4
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Diaphragm
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Blower cooled
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
0.172 liters per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
100.0 pounds per square inch gage
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Vertical
MRC:
The reciprocating design of the pump.AHZJ
Pump Reciprocating Design:
Single acting
MRC:
Indicates the type of reciprocating movement within the item.AHZN
Reciprocating Stroke Type:
Variable
MRC:
Indicates the type of device used to control the output or capacity of an item.AHZP
Volume Control Type:
Rotary
MRC:
Indicates the location of the control on the item.AHZQ
Control Location:
Center
MRC:
An indication of how the items are designed to operate in relation to each other.AHZS
Operation Relationship Design:
Simultaneous
MRC:
A measurement of the longest dimension of an item unencumbered by packaging or packing,in distinction from width.AJAF
Unpackaged Unit Length:
16.300 inches
MRC:
A measurement taken at right angles to the length of an item unencumbered by packaging or packing,in distinction from thickness.AJAG
Unpackaged Unit Width:
9.500 inches
MRC:
A measurement from the bottom to the top of an item unencumbered by packaging or packing,in distinction from depth.AJAH
Unpackaged Unit Height:
16.880 inches
MRC:
The element,compound,or mixture of the basic material of which the major portion of the pump is fabricated.AJAL
Pump Basic Material:
Iron
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
4.8 and 2.4
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
0.750-16 unf
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
0.750-16 unf
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.333 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0