رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Next assembly 13217742-01, used on e3/rsip
TXT
وصف:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.580 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
1 all components all secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
10 all components all primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
250.0 kilohertz single component
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.800 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Rsip ppl e/i fscm 09969
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns all components all winding
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 4 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01420 inches american wire gage all components all primary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage all components all secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
22 wire lead