رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Indicator, thrust, a/m37t engine test
TXT
وصف:
Engine Testing Thrust Indicator
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
Between 6.050 inches and 6.100 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
10.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 120.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.000 hertz
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Digital display
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+40000.0 pounds single indicator single scale
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
2
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Ms3102r-18-1s and ms3102r-14s-7p
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
5
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Aluminum
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Finish semi gloss black; output digital display; continuous 5 digit lighted numerical indication of engine thrust in pounds; accuracy +/- 10 lbs up to 10, 000 lbs and +/- 0.1% of reading above 10, 000 lbs; input signal source: summed output of 2 25, 000 lbs compression load cells; operation modes test or check, operate and range selector; adjustments: sampling rate, load cell zero balance, and range span calibration; operating temp 20 to 130 degrees f
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
Between 6.450 inches and 6.500 inches