رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Rotary Vacuum Pump Unit
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.333
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Hand carry
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded external
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Flexible coupled
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Air
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The specific gas with which the item is designed to be used.AENF
Specific Gas For Which Designed:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Sliding vane
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1725.0
MRC:
The device which prevents or reduces the amount of condensable vapors from entering and contaminating the item.AEQG
Vapor Condensation Preventative Device:
Gas ballast valving
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
3.0 cubic feet per minute in free air
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
150.0 degrees fahrenheit
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.1
MRC:
Designates the thread diameter and number of threads per measurement scale of the intake connection.CXCD
Err Default:
Err default
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0