رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Copper alloy
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tee angle
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Acetylene
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
External seat for gasket seal
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Unthreaded external tube
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, dual, top guided
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the type of renewable seating ring in the item.ADZH
Renewable Seat Ring Type:
Threaded
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Lug
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Manual, double stage
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Tee handle
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Dome
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
500.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
15.0 pounds per square inch
MRC:
The rated variance of the outlet pressure from the set pressure.AEWB
Outlet Pressure Accuracy Rating:
0.500 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included