رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Critical applications: poseidon matl (hull, mech., elec, ord. And elect.); trident matl
TXT
وصف:
Line Voltage Indicator
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-i-23830 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Polycarbonate plastic; 6.5 in. Lg; 3 in. W; 1.5 in. H; two flexible insulated test leads, 24 in. Lg, one black, one red; provides continuous response to voltage within the range of 25 to 600 vdc or vac (60 hz and 400 hz); two responding readouts min for fail-safe indications; provides independent indications and identifications of pos and neg term.; 60 and 400 hz power source indications and id; light emitting readouts or glow lamps w/constant glow or flashing indicators; voltage readouts respond to 28, 115, 220 and 440 vac or to 28, 115, 250 and 500 vdc; 1900 vrms dielectric withstanding k
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-i-23830 government specification