رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Direct Acting Reciprocating Pump
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
2
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
2
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, salt
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Piston
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
280.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
575.0 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
19.0 strokes per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Vertical
MRC:
The reciprocating design of the pump.AHZJ
Pump Reciprocating Design:
Double acting
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
4.000-8 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
5.000-8 npt