رقم الجزء 1548-0430302

Motor-tachometer Generator

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
1548-0430302
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
006351641
NSN
رقم المخزون الوطني:
6105-00-635-1641 6105006351641
TXT
وصف:
Motor-tachometer Generator
INC
INC
رمز اسم العنصر:
28454
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
2.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
3.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
2.000 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1245 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
40000.0 feet
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Separately excited
MRC:
The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
Calibration Speed In Rpm:
1000.0
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
0.2 ac
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
1.5 inch-ounces stalled
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
225.0 ac
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
3.500 watts input
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.375 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.625 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
25.0 operating degrees celsius and 85.0 operating degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
10000.0 single no load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.625 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
57.5 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A14 single style single end
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 wire lead

{lang[cimilar]} Motor-tachometer Generators