رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
155-115937-500
TXT
وصف:
Immer Electrical Heating Element
MRC:
The style designation indicating the configuration that most nearly corresponds to the mounting method of the item.AALX
Mounting Method Style:
Flange type mounting facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Flange, type
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
12
MRC:
The length of that portion of the heating element that imparts heat.ABHS
Effective Heating Length:
33.250 inches
MRC:
An indication of the radiation spectrum of the element.ABJA
Element Radiation Specificationtrum:
Noninfrared
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the element connection.ABJS
Element Connection Style:
Hermetically sealed stud
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
10.000 inches
MRC:
The number of holes or slots included.ABKT
Hole Or Slot Quantity:
8
MRC:
The number of heats at which the item will operate.ABNR
Heat Quantity:
1
Conduit Opening Size:
1.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
33.250 inches
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
9000.0 single voltage
MRC:
The number of elements in the item.BHHK
Element Quantity:
6
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
440.0 ac single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Three single voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper sheath