رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Terminal 1 is internally connect to terminal 7; terminal 12 is internally connected to terminal 9
TXT
وصف:
Saturable Reactor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.344 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.230 inches single group and 0.270 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal single component
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.407 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
3 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
4 control single component and 1 primary single component and 1 secondary single component
MRC:
The amount of control current beyond which an increase in control current produces no increase in the items output.CHTZ
Saturation Current Rating:
50.0 microamperes
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the base of an isosceles triangle.CQKH
Center To Center Distance Between Mounting Facilities Parallel To The Base Of An Isosceles Triangle:
1.078 inches single mounting facility single center group and 1.109 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.CSQJ
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle:
1.079 inches single mounting facility single center group and 1.110 inches single mounting facility single center group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
14 wire lead