رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Quiet design; reduced voltage operation with auto-local switch in auto position
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
22.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.765 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.109 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Automatic and manual
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
2
MRC:
A designation indicating the size by which the item is commercially known and/or identified.AJXE
Size Designator:
1
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Six 17/32 in. Diameter holes; rectangular pattern; 2 rows 3 ea spaced 7-1/4 in. C to c; 20 in. Cl to cl rows
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full or reduced
MRC:
The means used to reduce the electrical voltage.ANCP
Voltage Reduction Method:
Resistor
MRC:
The means used to restore the item to its full voltage.ANCQ
Full Voltage Restoring Method:
Time limit acceleration
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
5.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
250.0 dc
MRC:
The value of current for which the fuse is rated,expressed in amperes.ANDG
Fuse Current Rating In Amps:
10.0
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Undervoltage
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Splash proof
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Designed per nema std
MRC:
An indication of the various functional switching positions.ANRK
Switch Functional Positions:
Automatic and start and stop and local
MRC:
Indicates the type of control.AQZF
Control Type:
Local or remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit protection fuse