رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Control Transformer Synchro
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.7700 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1872 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.5000 inches single shaft
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
15
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
115.0
MRC:
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
Stator Input Current Rating:
24.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
Stator Input Electrical Power Rating:
600.0 milliwatts
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The number of individual teeth on the splined portion of the shaft.AJVM
Spline Tooth Quantity:
21 single shaft
MRC:
The number of teeth the splined shaft has per inch of pitch diameter.AJXA
Spline Tooth Diametral Pitch:
120 single shaft
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Spline single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
0.735 rotor to stator
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 screw