رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Signal Generator
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Bench
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+6.950/+11.000 gigahertz
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
3
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Polarad electronics corp
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
50.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts and 230.0 volts
MRC:
Indicates the type of modulation provided.AYYE
Modulation Type:
Am and fm and pulse and square wave
MRC:
The name of the accessory component assigned by the controlling agency.AZCG
Accessory Component Name:
Rf cable assembly, line cord adapter, wrench kit
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 0.5 percent accuracy
MRC:
An indication of the calibrated signal range that is output by the item.BHFZ
Calibrated Signal Output Range:
Plus 3 dbm to minus 127 dbm
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
5 mw from 6.95 to 11.00 ghz
MRC:
Indicates the location of the modulator on the item.BHGD
Modulator Location:
Internal
MRC:
The number of complete cyclic changes,per unit of time,for which the pulse repetition is rated.BHQF
Pulse Repetition Frequency Rating:
Between 10.0 hertz and 10.0 kilohertz
MRC:
The number of alternating current phases.FAAZ
Phase:
Single