رقم الجزء 162BL403C

Electrical Temperature Indicator
وصف

Temperature ind.

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
162bl403c
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
011129463

معلومات الجزء
Yellow arc from 146.0 degrees c to 163.0 degrees c; yellow line at 11.2 degrees c rise red line at 163.0 degrees c; scale calibration: 10 degrees c, 5 degrees c; scale name: outlet temperature, rise; electrical connection controlling agency: lewis; instrument lamp: included; panel mounted body size: 1.812 in.Nom; illumination method: lamp

NSN
رقم المخزون الوطني:
6685-01-112-9463 6685011129463
TXT
وصف:
Electrical Temperature Indicator
INC
INC
رمز اسم العنصر:
03380
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
2.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
4.876 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
10
MRC:
An indication of the scale range.APSK
Scale Range:
+0.1/+20.0 degrees celsius 2nd indicator 2nd scale
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
26e10a2a
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Clock-hand all pointers
MRC:
The means by which the illuminated color is generated.AWHH
Illumination Color Generation Method:
Integral light
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 panel
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Lamp socket

{lang[cimilar]} Electrical Temperature Indicators

« Pressure, Temperature and Humidity Measuring and Controlling Instruments {lang[catalog]}
قارن الآن»
واضح | أخفى