رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
16icxxxxxxxa5bbxxx01
معلومات الجزء
6.000 in. Diameter dial; dual snap action switch; 180 degree arc; 3 percent accuracy; scale no. 00209571
TXT
وصف:
Diff Fluid Flow Indicating Meter
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Flush
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
6.500 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum, cast
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
5.250 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Stainless steel sensor and housing, 1
MRC:
Designates the size of the inlet connection included on the item.ANHY
Inlet Connection Size:
7/16 in. 20 thd unf
MRC:
The general outside configuration of the case.ANRX
Case Shape:
Round
MRC:
An indication of the presentation range of the scale.ASPF
Scale Presentation Range:
Bellows unit assembly 0 to 50 range of numerical markings and indicator 9.9 to 40.74 range of numerical markings
MRC:
Indicates the type of pressure.AXAF
Pressure Type:
Low or high
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
Black markings on white background
MRC:
Designates the size of the outlet connection included on the item.BMWJ
Outlet Connection Size:
7/16 in. 20 thd unf
MRC:
The maximum differential pressure which the item is capable of withstanding without evidence of deformation or other damage.CPYY
Maximum Differential Pressure:
Bellows unit assembly 50.0 in. Of water column and indicator 40.74 in. Of water column
MRC:
An indication of whether or not a totalizing integrator register is included.CPZB
Totalizing Integrator Register:
Not included
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Cpyy and feat