رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.800 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
112 single component single winding
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Swinging
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.16 millihenries single component single winding and 1.59 millihenries single component single winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
10.0 kilohertz single component
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.770 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
100.0 degrees celsius
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding and winding turns single component single winding
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches single group
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.04030 inches american wire gage single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
2.0 amperes dc single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
107.000 single component single winding
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead