رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Waveguide Assembly
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Directional antenna
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless all tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.40
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.10
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
6.0 pounds per square inch gage
Waveguide Center To Center Distance:
8.500 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible all tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint all tubing segment all surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Double bend type