رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Centrifugal Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
1400.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
25.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Mixed
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Salt water
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
Gas Cooling Equipment Type:
Liquid type aftercooler
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The design of a nonpositive displacement centrifugal compressor as determined by the direction of flow,with respect to the axis,of the compressed gas.AAYC
Centrifugal Compressor Design:
Axial flow
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The steam pressure required to motivate the steam engine or turbine used as the prime mover.AAYL
Steam Operating Pressure:
585.0 pounds per square inch gage
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Round flange
MRC:
Indicates a device used to eliminate the noise of the intake or discharge of the item.AAZA
Silencer Type:
Inlet
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Steam turbine
MRC:
Indicates the type of safety device(s) provided.BPRZ
Safety Device Type:
Relief valve
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
337.8 degrees celsius steam