رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Line sag/surge range without going to battery: 80-140.160-264 vac; transfer time to battery: none (uninterrupted); battery reserve time: 6 minutes at full load; recharge time: 5 hours to 95% after full load discharge; battery rating: 48 vdc; battery replacement time: < 5 minutes; oper temp 0 to 40 degrees c; storage temp range: -15 to +50 degrees c; weight: 81.5 lbs w/battery pack, 28 lb removable pack; input power cord: 6" with 5-20p plug; output receptacles: four 5-20r, one 5-20r aux
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.000 inches
MRC:
The number of batteries required for operation.AEXR
Battery Quantity:
1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
7010-01-540-0501 - master reference terminal (mrt)
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
127.0 ac volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
100.0 ac volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
110.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
115.0 ac volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 ac volts 4th power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
40.0 hertz single operating power rqmt and 70.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
60.0 hertz 2nd power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
16.0 ac amperes single operating power rqmt
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
Indicates the location of the battery.CWJF
Battery Location:
Internal