رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread.AAJE
Thread Pitch Diameters:
+0.0958/+0.0991 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Oval, open, wire lug
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Not rated
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
12.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.750 inches
Center Hole Length:
8.000 inches
Center Hole Width:
1.500 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
Not rated
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
3
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Not rated
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
Not rated
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
Not rated
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
Not rated
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.625 inches
MRC:
The number of steps provided.ATPC
Step Quantity:
2
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Threaded hole
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Transmission line
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Adjustable
MRC:
The amount of time delay between adjacent step settings.CCDP
Delay Time Per Step:
Any acceptable
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
Not rated
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
Not rated
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
4 coaxial receptacle
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.THDS
Thread Size And Series/type Designator:
0.112-40 unc