رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Control Transformer Synchro
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
8
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
11.8
MRC:
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
Stator Input Current Rating:
103.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
Stator Input Electrical Power Rating:
218.0 milliwatts
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The magnitude part /z/ of the stator impedance with the rotor open /zso/,expressed in ohms.AJTJ
Zso Impedance Magnitude In Ohms:
570.00
MRC:
The angle part /o/ of the stator impedance with the rotor open /zso/,expressed in degrees.AJTK
Zso Impedance Angle In Deg:
81.00
MRC:
The magnitude part /z/ of the rotor impedance with the stator shorted /zrs/,expressed in ohms.AJTL
Zrs Impedance Magnitude In Ohms:
940.00
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
25.00 output
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
30.00