رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz all components
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Three phase to three phase all components
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 1st component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 1st component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 2nd component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 2nd component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 3rd component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet 3rd component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac pounds per hour wet all components all primary input
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
21.00 ac pounds per hour wet 3rd component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
16.50 ac pounds per hour wet 1st component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
16.50 ac pounds per hour wet 2nd component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
19.00 ac pounds per hour wet 1st component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
19.00 ac pounds per hour wet 2nd component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
19.00 ac pounds per hour wet 3rd component 3rd secondary