رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Nonwire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.078 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.547 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.500 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.531 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.500 inches
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Flush drive with slot-hole
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
295.0
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
3.00 inch-ounces
MRC:
The maximum amount of force requred to maintain actuator movement.AEFL
Maximum Running Torque:
0.25 inch-ounces
MRC:
The maximum amount of turning force that can be applied through the operating shaft with0ut damage to the stops.AEFM
Maximum Stop Torque:
10.00 inch-ounces
MRC:
The center to center distance between terminals.AEHT
Center To Center Distance Between Terminals:
0.200 inches
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
2.0 kilohms single section
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
295.0
MRC:
The center to center distance between the center terminal and the outside terminal.CQCM
Center To Center Distance Between Center Terminal And Outside Terminal:
0.100 inches
MRC:
The change in total resistance over a specified temperature range per section,expressed as a percent of the total resistance at a specified reference temperature.CQDB
Resistance Tempurature Characteristic Range Per Section In Percent:
-0.0/+4.5 -55 degrees celsius single section and -0.0/+2.5 -25 degrees celsius single section and -0.0/+1.5 0 degrees celsius single section and -0.0/+0.0 25 degrees celsius single section and -1.5/+1.5 85 degrees celsius single section and -0.0/+3.5 120 degrees celsius single section
MRC:
The change in total resistance over a specified temperature range per section,expressed as a percent of the total resistance at a specified reference temperature.CQDB
Resistance Tempurature Characteristic Range Per Section In Percent:
-0.0 to 4.5 -55 degrees celsius single section and -0.0 to 2.5 -25 degrees celsius single section and -0.0 to 1.5 0 degrees celsius single section and -0.0 to 0.0 25 degrees celsius single section and -1.5 to 1.5 85 degrees celsius single section and -0.0 to 3.5 120 degrees celsius single section
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
120.0 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
0.25 free air single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0 to 10.0 single section
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Stops
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
70.0 single section
MRC:
The rate of change and distribution of resistance per section,in relation to the rotation of the control shaft,which establishes a standard taper curve designated by an alphabetic character and accepted for common usage.CSDL
Standard Taper Curve Per Section:
A single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 pin