رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electrical Receptacle Connector
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape threaded
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.420 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 1.005 inches and 1.030 inches
Distance From Mounting Shoulder To Front Face:
0.656 inches
Mounting Facility Thickness:
0.093 inches
MRC:
Indicates the type of threaded device included on the item.AFQR
Threaded Device Type:
Mounting bushing
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
27-5 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
7.5 single mating end single contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
500.0 single mating end single contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
700.0 single mating end single contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Mating end
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Ball
MRC:
A nominal measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AKMG
Thread Length:
0.281 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.000 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Rubber single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Solder well single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Aluminum alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Cadmium
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
19 single mating end single contact grouping
MRC:
The physical configuration of the hole designed to accommodate a bushing.CXCJ
Bushing Accommodation Hole Shape:
Round
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Round pin single mating end single contact grouping
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
10001-2119726 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Quality controlled for polaris